What does "clean" cannabis mean on a lab report?
The short answer
"Clean" is not a term a lab report uses. On a certificate it can only mean two checkable things: the batch passed every contaminant panel (pesticides, heavy metals, residual solvents, microbes and mycotoxins), and the certificate lists each of those results by name so you can see it. 100.0% of 1,241 finished products with a verdict passed in California, and 99.9% of 5,264 finished products with a verdict passed in New York. Passing is not the same as nothing found: in California, 1.6% of itemized pesticide panels show a trace below the legal limit, and in New York, 4.8% of itemized pesticide panels show a trace below the legal limit. How often a trace shows up depends partly on the lab, so a brand's "nothing detected" record partly reflects which lab it uses. A certificate also says nothing about anything it did not test, such as added flavorings, unless they are listed on it.
What the panels found
Finished products whose certificate lists each analyte by name. A trace is a measurable result under the limit, which still passes.
| Market | Panel | Certificates | Nothing found | Trace under limit | Over limit |
|---|---|---|---|---|---|
| California | Pesticides | 1,238 | 98.4% | 1.6% | 0.0% |
| California | Heavy metals | 356 | 52.5% | 47.5% | 0.0% |
| California | Residual solvents | 168 | 19.6% | 80.4% | 0.0% |
| California | Mycotoxins | 356 | 100.0% | 0.0% | 0.0% |
| New York | Pesticides | 4,791 | 95.2% | 4.8% | 0.0% |
| New York | Heavy metals | 4,718 | 51.8% | 48.2% | 0.0% |
| New York | Residual solvents | 4,215 | 76.3% | 23.6% | 0.1% |
| New York | Mycotoxins | 4,712 | 99.9% | 0.1% | 0.0% |
Why “nothing detected” depends on the lab
Heavy metals are a good example. Every lab tests the same metals, but each has its own detection floor. Keystone State Testing of New York finds a measurable metal on 96.0% of the certificates it issues, while Green Analytics NY, LLC does on 10.1%. Part of that gap can come from the products each lab sees, but each lab also has its own floor, and a trace under a lab's floor is reported as nothing found. That is why a brand-by-brand “cleanest” ranking built on traces would partly be ranking labs, and why this page does not publish one.
| Laboratory | Market | Metals certificates | With a measurable metal |
|---|---|---|---|
| Keystone State Testing of New York | New York | 375 | 96.0% |
| DRS Testing | New York | 241 | 66.4% |
| Phyto-Farma Labs | New York | 435 | 55.6% |
| Excelbis Labs | California | 142 | 53.5% |
| Smithers CTS New York LLC | New York | 913 | 51.7% |
| SC Laboratories California LLC | California | 167 | 47.9% |
| ACT Laboratories | New York | 1,842 | 46.2% |
| Certified Testing and Data | New York | 143 | 34.3% |
| Kaycha Labs | New York | 440 | 25.2% |
| Green Analytics NY, LLC | New York | 257 | 10.1% |
How to check a product yourself
Find the certificate for the batch number on your package, not a sample report. Check that it shows a pass for every contaminant panel and lists each result by name. For a vape, if you care about cutting agents or added flavor, search the certificate for them by name: if an additive is not listed, it was not tested, and a pass on the other panels says nothing about it. The verification guide and how to read a COA cover each step, and search finds a batch in this index.
Method
Population: finished-product certificates from California and New York that list a panel's analytes by name. Nothing found means no analyte on the panel carries a measured result above zero; totals and sums are not counted as separate findings. Over limit means a result above the printed limit or an analyte the lab marked as failing. The lab table shows labs with at least 100 itemized metals certificates. What this page cannot show: products without public certificates, and anything a lab did not test. Figures recompute on every build; scope is on the methodology page.